Product description
Control panel and keypad set SECOLINK PAS808+KM20B
Specifications
SKU
U-3816948
Product code
CASPAS808KM20B
Supplier product description
- 8 wired zones on the board
- 3 PGM outputs
- 4 areas
- 5 users
- Up to 7 keyboards
- PSTN communicator
Control panel | |
On-board wired zones | 8 |
2-wire smoke detector input | - |
On-board wireless zones | - |
Maximum zones in system | 8 |
On-board PGM | 3 |
Maximum PGM in system | 8 |
User + installer codes | 5+1 |
Duress code | X1, X2, X3, X4 (when X4 = X4 + 1) |
Defaulting user code | Yes |
Key switch zone | - |
Partitions | 4 |
"Shared" partition (common area) | - |
System timers | - |
Maximum keypads/modules in system | 7 |
Event log buffer | 512 |
PSTN communicator | In-built |
In-built interface for backup communicator | TTL Serial |
Data bus protocol | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 4 |
Maximum phone numbers for personal dialing | Up to 4 |
Maximum phone numbers for CMS reporting | Up to 4 |
Reporting protocol | Contact ID |
Voice guide for system control over PSTN | - |
Voice guide for system programming over PSTN | - |
"Roller" detector type | - |
"Vibration" detector type | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): | ≤1.2 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
Maximum current out of +AUX | +0.8 A |
Maximum current out of +BELL | +0.8 A |
Maximum current into -PGM | -0.05 A |
Maximum current out of +PGM | +0.8 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | - |
Failed (waste) backup battery disconnection | - |
Maximum battery charging current | +0.4 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | -10oC up to +50oC |
Production status | In production |
Latest firmware version | v0.03 |
In-field firmware upgrade (by USB) | - |
Keypad | |
On-Board zones | 2 |
On-Board PGM | - |
Ambient temperature measurement | - |
LCD type | 2 rows 16 symbols each |
Keys in keypad | 20 |
Programmable fast keys (F-Keys) | 32 |
Data bus protocol | KRBUS |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Maximum wiring distance to CP | 300 m |
Power supply | 9 - 14 V |
Voltage measurement on keypad | Yes |
Current consumption | Backlight on 100 mA, Baclight off < 50 mA. |
On-Board sounder | Buzzer |
Backlight color | Display = blue, keypad = yellow |
Character set | Latin, Russian, Greek, East European, West European, Azeri, Turkish, Scandinavian. |
User interface type | Advanced, Simple, Baltic, Asian. |
Overall dimensions W x H in mm | 115 x 95 |
Environmental compliance | ROHS |
Operating temperature | 0oC up to +50oC |
Interface for keypad settings programming | USB |
Interface for keypad firmware updating | USB |
Supplier parameters
Category
Control Panels
Product code
CASPAS808KM20B
Supplier's product code
CASPAS808KM20B
Product ID
U-3816948
The information that supplier provides may differ from the actual product. If you noticed an error please let us know by email: [email protected].