Benchtop multimeter; colour,LCD TFT 4,3"; 6,5 digit; 480x272
ΠΠΎΠ»Π΅Π·Π½Π°Ρ ΠΈΠ½ΡΠΎΡΠΌΠ°ΡΠΈΡ
ΠΠ°ΡΠ°ΠΌΠ΅ΡΡΡ ΡΠΎΠ²Π°ΡΠ° ΠΏΠΎΡΡΠ°Π²ΡΠΈΠΊΠ°
Product code
GDM-9060GP
Supplier's product code
GDM-9060GP
Product ID
U-195425
AC current measuring accuracy
Β±(0.13% + 0.04% range)
AC current measuring range
1A
AC voltage measuring accuracy
Β±(0.09% + 0.04% range)
AC voltage measuring range
1...750V
DC current measuring accuracy
Β±(0.05% + 0.005% range)
DC current measuring range
10A
DC voltage measuring accuracy
Β±(0.014% + 0.001% range)
DC voltage measuring range
1kV
Display parameters
6,5 digit
Display resolution
480x272
Interface
RS232
Kind of display used
LCD TFT 4,3"
Manufacturer
GW INSTEK
Measurement
AC voltage
Measurement memory
100000
Resistance measuring accuracy
Β±(0.014%+0.001% range)
Resistance measuring range
10kΞ©
Sampling
1000x/s
Software
included
Standard equipment
mains cable
Temperature measuring range (with E-type thermocouple)
-200...1372Β°C
Temperature measuring range (with J-type thermocouple)
-200...1372Β°C
Temperature measuring range (with K-type thermocouple)
-200...1372Β°C
Temperature measuring range (with R-type thermocouple)
-50...1870Β°C
Temperature measuring range (with S-type thermocouple)
-50...1870Β°C
Temperature measuring range (with T-type thermocouple)
-200...1372Β°C
Temperature measuring range with N-type thermocouple
-200...1372Β°C
Type of meter
benchtop multimeter
True effective value measurement
True RMS AC
Brand
GW INSTEK