Pristatymo terminai
2024-11-28 Numatomas pristatymas užsakius dabar
Prekė užsakoma iš tiekėjo sandėlio. Jei tiekėjas šios prekės pristatyti iki nurodytos datos negalės, informuosime jus el. paštu.
Yra | Tiekėjo sandėlis |
Pristatymas į namus
Perdavę prekes kurjeriui, informuosime Jus el. paštu.
Virš 50,00 € (Užsakymams iki 1000 kg) | Nemokamai |
Iki 50,00 € (Užsakymams iki 3 kg) | 3,49 € |
Iki 50,00 € (Užsakymams iki 1000 kg) | 4,99 € |
Pristatymas į paštomatą
Perdavę prekes kurjeriui, informuosime Jus el. paštu. Užsakymai virš 50.00 € pristatomi nemokamai.
2,39 €
Prekės aprašymas
Control panel and keypad set SECOLINK P32+KM24G
Specifikacijos
SKU
U-2527874
Prekės kodas
CASP32KM24G
Tiekėjo prekės aprašymas
- 7/14 wired areas
- Connection of two-wire smoke detectors
- 32 wireless zones
- 3 PGM outputs
- 31 users
- 4 areas
- Up to 15 keyboards
- 512 event memory
- Contact ID
- EN50131, Grade2
Control panel | |
On-board wired zones | 7/14 (doubling) |
2-wire smoke detector input | 1 |
On-board wireless zones | 32 |
Maximum zones in system | 32 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 31+1 |
Duress code | |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
"Shared" partition (common area) | Yes |
System timers | 16 |
Maximum keypads/modules in system | 15 |
Keypad compatibility | All SECOLINK keypads |
Event log buffer | 512 |
PSTN communicator | Plug-on |
In-built interface for backup communicator | TTL Serial |
Data bus protocol | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 9 |
Maximum phone numbers for personal dialing | Up to 5 |
Maximum phone numbers for CMS reporting | Up to 4 |
Reporting protocol | Contact ID |
Voice guide for system control over PSTN | Yes |
Voice guide for system programming over PSTN | Yes |
"Roller" detector type | Yes |
"Vibration" detector type | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) | ~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge) | ≤2.0 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
Maximum current out of +AUX | +1 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM | -0.3 A |
Maximum current out of +PGM | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.35 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | -10oC up to +50oC |
Production status | In production |
Latest firmware version | v0.03 |
In-field firmware upgrade (by USB) | Yes |
Keypad | |
On-Board zones | 2 |
On-Board PGM | 1 (open collector up to 15 mA) |
Ambient temperature measurement | Yes |
LCD type | Graphic: 240 x 120 dots |
Keys in keypad | 24 |
Programmable fast keys (F-Keys) | 32 |
Data bus protocol | KRBUS |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Maximum wiring distance to CP | 300 m |
Power supply | 9 - 14 V |
Voltage measurement on keypad | Yes |
Current consumption | Backlight on 80 mA, Backight off < 68 mA. |
On-Board sounder | Speaker |
Backlight color | Display = blue, keypad = blue |
Character set | Major character sets of the world. |
User interface type | Navigation menu with short help text system. |
Overall dimensions W x H in mm | 92 x 133 |
Environmental compliance | ROHS |
Operating temperature | 0oC up to +50oC |
Interface for keypad settings programming | USB |
Interface for keypad firmware updating | USB |
Tiekėjo specifikacijos
Category
Control Panels
Product code
CASP32KM24G
Supplier's product code
CASP32KM24G
Product ID
U-2527874
Tiekėjo pateikiama informacija apie prekę gali skirtis nuo realaus produkto. Jei pastebėjote neatitikimų praneškite apie tai el. paštu [email protected].